This case describes the discovery and subsequent attempts at removal of a migrated venous stent.

Case report

Figure 2. Transthoracic echocardiogram: parasternal short axis view (aortic valve level)

Figure 2. Transthoracic echocardiogram: parasternal short axis view (aortic valve level)

Figure 1. Transthoracic echocardiogram: apical four-chamber view

Figure 1. Transthoracic echocardiogram: apical four-chamber view

A 38-year-old man with pelvic chondro-sarcoma diagnosed in 1999 had a right femoral venous stent for extrinsic compression by the tumour in June 2004. Two months later, computed tomography (CT) scan of the chest with a view for chemotherapy unexpectedly showed the venous stent within the right heart.

Though asymptomatic, he was referred for catheter retrieval of the venous stent, as potential serious complications include thrombus formation, pulmonary embolism, sepsis, endocarditis, myocardial perforation and cardiac tamponade. Transthoracic echocardiogram showed the stent was lodged across the tricuspid valve (figures 1 and 2).

The procedure was performed with vascular and cardiothoracic surgical backup. A 14-French sheath was used via the left femoral vein. The stent was retracted down to the left iliac vein after eventually catheterising the stent under fluoroscopy with a large loop snare (figures 3 and 4), following an initially unsuccessful attempt with a Dormier catheter. One strut was splayed in the right atrium remote from the stent prior to the start (arrow), and was not retrieved, as it was certainly endothelialised.

Figure 4. Screening: left anterior oblique – caudal view

Figure 4. Screening: left anterior oblique – caudal view

Figure 3. Screening: right anterior oblique – caudal view

Figure 3. Screening: right anterior oblique – caudal view

The stent size could not allow withdrawal without surgery and it was decided to deploy it in the left iliac vein with a 9/40 mm balloon. Thrombus was noted locally and extracted, followed by anticoagulation with heparin for 48 hours and planned warfarin for three months. Post-procedure transthoracic echocardiogram was normal.

Discussion

Venous stents can migrate into cardiac cavities or the pulmonary artery. The diameter of the stent must exceed that of the designated vein to prevent migration as respiratory movements induce great variability in the diameter of the vein.

Conflict of interest

None declared.

In the near future, you will need to be a registered user to view full articles

Already a member? Login now

Register Now

Close

back to top

Comments

There are currently no comments for this article - leave a comment

You must be logged in to post a comment.
Not yet a member? Register now for free.

back to top

Close

You are not logged in

You need to be a member to print this page.
Sign up for free membership, or log in.

Find out more about our membership benefits

Close

You are not logged in

You need to be a member to download PDF's.
Sign up for free membership, or log in.

Find out more about our membership benefits